Q-Explosion Proof Floodlight
- ICAO annex 14, CAP437
Safe area Atex / Zone 1
Certificates
Technical details
Datasheet, Manuals and Drawings
Details Q-Explosion Proof Floodlight
The Q-Explosion Proof Floodlight is a CAP437 compliance 5000 cd floodlight for hazardous areas. The Q-Explosion Proof Floodlight is available in several configurations such as 100-240 VAC and 24 VDC.
The floodlighting should be arranged so as not to dazzle the pilot and, if elevated and located off the landing area clear of the Limited Obstacle Sector (LOS), the system should not present an obstacle to helicopters landing and taking off from the helideck. All floodlights should be capable of being switched on and off at the pilot"s request. Setting up of lights should be undertaken with care to ensure that the issues of adequate illumination and glare are properly addressed and regularly checked. For some decks it may be beneficial to improve depth perception by floodlighting the main structure or "legs" of the platform.
Order code Q12RI01 – Explosion Proof Floodlight
Q12RI01–11R1 Input power: 100-240 VACQ12RI01–12R1 Input power: 24 VDC
Q12RI01–ALR1 Aluminium, Powder coated Housing
Q12RI01–SSR1 SS316, Powder coated Housing
Additional Information
Article Number: | Q12RI01 |
Manufacturer: | Q-Aviation B.V. |
HS-Code: | 94054039 |
Warranty: | 2 Years |
Product Specifications Q-Explosion Proof Floodlight
Application: | Helideck |
Zone: | Zone 1 or 2 |
Light Color: | White (5700K) |
Light Source: | LED, steady burning |
Light Intensity: | 5.000 cd |
Enclosure: | Aluminium, Powder coated RAL5015 / Borosilicate glass |
Mounting: | Rigid, 4x M8 |
Input Voltage: | 100-240 VAC or 24 VDC |
External earthing: | up to 4mm2 / AWG 12 |
Tested Ambient Temp: | -25°C to + 60°C |
Cable side entries: | 2 x M25x1.5 |
Cable bottom entry: | 1 x M25x1.5 |
Cable size: | 12 - 19mm |
Cable stops included : | 1 x M25x1.5 |
Consumption: | 8 Watt |
Life expectancy: | 100.000+ hours |
Cable: | H07RN-F 3x2,5mm² |
Suitable For: | Hazardous Area |
Earth Connection: | up to 4mm2 / AWG 12 |
Ingress Protection: | IP67 |
In Compliance With: | ICAO annex 14, CAP437 |
Hazardous area: | IECEx/Atex Zone 1 and 2 |
Class: | Zone 1 Hazardous Area |
Cable glands included: | 2 x M25x1.5 |
Cable stops included : | 1 x M25x1.5 |
Ip index: | IP67 |
Inrush Current: | 70A / 120µs |
MAX. No. of units: | 20 units on a C16A Circuit breaker |
IECEx Certificate no.: | IECEx ITS 18.0052X |
Size and Dimension
Weight: | 5.1 Kg |
Dimension: | 255x159x168 mm (LxWxH) |
Dimension Packaging: | 250x250x250mm (LxWxH) |