Q-Explosion Proof Perimeter Light
- ICAO annex 14, CAP437
Safe area Atex / Zone 1
Certificates




Technical details



Datasheet, Manuals and Drawings




Details Q-Explosion Proof Perimeter Light
Lighting assemblies
The Q-Explosion proof Perimeter Light is the 50 cd perimeter Light for Hazardous Area offshore facilities.
The Q-Explosion proof Perimeter Light is in compliance with the CAP437 regulation and the light is available in several configurations such as 230 VAC and 24 VDC.
Operation
Perimeter lights, spaced at intervals of not more than 3.0 m, should be fitted around the perimeter of the landing area of the helideck.
For any helideck where the D-value is greater than 16.00
m, the perimeter lights should not exceed a height of 25cm above the surface of the helideck.
Order code Q10RI01 – Explosion Proof Perimeter Light
Q10RI01–11R1 Input power: 100-240 VACQ10RI01–12R1 Input power: 24 VDC
Q10RI01–ALR1 Aluminium, Powder coated Housing
Q10RI01–SSR1 SS316, Powder coated Housing
Additional Information
Article Number: | Q10RI01 |
Manufacturer: | Q-Aviation B.V. |
HS-Code: | 94054039 |
Warranty: | 2 Years |
Product Specifications Q-Explosion Proof Perimeter Light
Application: | Helideck |
Zone: | Zone 1 or 2 |
Light Color: | Green, 530nm |
Light Source: | LED, steady burning |
Light Intensity: | 50 cd |
Vertical Beam Profile: | as per CAP437 |
Colour chromaticity: | As per ICAO |
Enclosure: | Aluminium, Powder coated RAL5015 / Borosilicate glass |
Mounting: | Rigid, 4x M8 |
Input Voltage: | 100-240 VAC or 24 VDC |
External earthing: | up to 4mm2 / AWG 12 |
Tested Ambient Temp: | -25°C to + 60°C |
Cable side entries: | 2 x M25x1.5 |
Cable bottom entry: | 1 x M25x1.5 |
Cable size: | 12 - 19mm |
Cable stops included : | 1 x M25x1.5 |
Consumption: | 8 Watt |
Life expectancy: | 100.000+ hours |
Cable: | H07RN-F 3x2,5mm² |
Suitable For: | Hazardous Area |
Earth Connection: | up to 4mm2 / AWG 12 |
Ingress Protection: | IP67 |
In Compliance With: | ICAO annex 14, CAP437 |
Hazardous area: | IECEx/Atex Zone 1 and 2 |
Class: | Class 1 Hazardous Area |
Cable glands included: | 2 x M25x1.5 |
Cable stops included : | 1 x M25x1.5 |
Ip index: | IP67 |
Inrush Current: | 70A / 120µs |
MAX. No. of units: | 20 units on a C16A Circuit breaker |
Size and Dimension
Weight: | 4.2 Kg |
Dimension: | 183x183x150 mm (LxWxH) |
Dimension Packaging: | 200x200x200 mm (LxWxH) |